Skip to main content

Table 3 Longitudinal OCT results of MOG-IgG-seropositive patients and HCs

From: Optical coherence tomography in myelin-oligodendrocyte-glycoprotein antibody-seropositive patients: a longitudinal study

Longitudinal OCT data

HC

MOG-IgG-seropositive patients EyeON-

MOG-IgG-seropositive patients EyeON+

HC vs MOG-IgG-seropositive patients (EyeON- and EyeON+)

EyeON- vs EyeON+

Absolute change to baseline

 

N (eyes) = 56

N (eyes) = 18

N (eyes) = 20

[B]

[95%CI]

[SE]

[p]

[B]

[95%CI]

[SE]

[p]

GCIP [mean (SD)]

0.00 (0.01)

0.00 (0.01)

0.00 (0.05)

− 0.000

− 0.004; 0.005

0.002

0.884

− 0.006

− 0.016; 0.003

0.005

0.214

pRNFL [mean (SD)]

− 0.61 (2.00)

− 4.5 (5.89)

− 1.60 (4.48)

− 1.645

− 2.819;

− 0.471

0.599

0.009

0.168

− 1.380; 1.717

0.790

0.832

INL [mean (SD)]

0.00 (0.01)

0.01 (0.02)

0.00 (0.03)

0.002

−0.002; 0.005

0.002

0.312

− 0.003

− 0.011;

0.004

0.004

0.381

MV [mean (SD)]

0.00 (0.02)

− 0.01 (0.04)

− 0.01 (0.05)

− 0.008

− 0.016; 0.0013

0.004

0.103

0.002

− 0.013; 0.018

0.008

0.769

  1. Abbreviations: 95%CI 95% confidence interval, B Estimate (beta-coefficient), GCIP combined ganglion cell and inner plexiform layer, HC healthy control, INL inner nuclear layer, EyeON- MOG-IgG-seropositive patients without a history of ON, EyeON+ MOG-IgG-seropositive patients with a history of ON, OCT optical coherence tomography, p p value, pRNFL peripapillary retinal nerve fiber layer, SD standard deviation, SE standard error, MV macular volume, vs versus, N number of eyes